采购单位:永卓控股有限公司 项目编号:XM20260904235609 寻源方式:询比价 领域类别:资材备件 创建部门:资材备件科 发布时间:2026-09-04 09:02:57 开标时间:2026-09-09 12:00:00 保证金(万元):2000 采购员:郭家腾 联系方式:0512-58906926 序号物资名称规格型号材质计划数量单位附件1引伸计WANCE-EX05015 准确度0.5级,附有效期内检定/校准证书2个4_引伸计说明书WANCE.pdf 报价地址: https://yzsrm.yong-gang.cn/#/portal/enquiryDetail?projectId=050fcc55a84740bd80577831a7b5adc7&statustype=cg附:传感器接线图,FunctionsThisisageneralpurposeextensometerforaxialtensileandcyclictesting.Theseextensometersaredesignedfortestingawiderangeofmaterials,includingmetals,plastics,composites,etc.Thedualflexuredesignmakesthemveryruggedandinsensitivetovibrations,whichpermitshigherfrequencyoperation.ThiscomesstandardwithMP'sQuickAttackKit,makingiteasytoquicklymounttheextensometeronthetestspecimenwithonehand.StructureA.QuickAttachKitadjustmentblock.Setscrewsinthisblockcanbeloosenedtoallowforthefine-tuningofwireformandplungerposition.B.Springorelasticbandattachmentposts.TheQuickAttackKitmayberemovedtoallowspringsorelasticbandstoattachtheextensometertothetestspecimen.C.Knifeedges.Thesecanbereplacediftheybecomeworn.Wewillreserveanestofknifeedgesforeveryextensometer.D.Zeropin.Usedtosettheinitialgaugelengthoftheextensometer.E.Wireforms.Eachextensometerallequippedtwokindsofdifferentwireforms,Availableforbothflatandroundspecimens.Seefigare2F.Springplungers.Pressthesetoextendthewireformsandattachtheextensometertothesample.EB,A,FCDFigare1WireformsofflatspecimensWireformsofroundspecimens2.2.2.2.温度影响出厂时,所有引伸计标定都是在室温下进行,环境比较稳定,输出Figare2,值也是比较稳定。当所处的环境温度发生改变时,标定的零点位置也会发生相应Specifications,的改变,这是正常现象,不影响测量精度,客户只需要在所处的工作温度下重新Excitation:5DCVrecommended,进行标定一下即可。Bestfitspan:1to4mV/V,nominal,dependingonmodel.3.3.3.3.如果购买的引伸计的转接器套件的标距长度不同,可以按照下面的提示修改Linearity:typically-0.5%to0.5%offullscalemeasuringrange,dependingon,计量长度。model.(1).取出螺丝,拿下钢丝挂钩安装板。TemperatureRange:normaltemperature(23±5ºC).Cable:integral,ultra-flexiblecable,5m.(2).去除钢丝挂钩。StandardQuickAttackKit:Fitsroundsamplesupto25mmdiameterandflatsto,(3).安装新钢丝挂钩。12mmthick,(4).拧紧所有的紧固件,使引伸计的钢丝挂钩平行,零位销进出自由。如果零位Standards,销比较紧,可以调节一下引伸计上的钢丝挂钩,直到可以自由进出为止。ASTME83,ISO9513,GBT12160,JB6146,JBT6146,JJF1096,JJG762,JJG762挂钩固定块Inspectionbeforeuse1.Inspecttheknifeedgestoensurethatthereisnoexcessivewearpresent.Asparesetofknifeedgesareincludedwiththeextensometerforreplacement.2.Adjustattachmentforcetopreventtheknifeedgesfromslippingonthesample.Whentheextensometerismountedtothesample,theknifeedgesshouldexerttensiononthesampleadequatetokeeptheminplacethroughouttesting,butnotenoughtodamagethesample.yourextensometerwasprovidedwithaquickattackkitandwireformsinstalled.Youmayfine-tunetheattachmentforcebyadjustingthepositionofthespringplungersandwireformsusingthesetscrews.Toincreasespringtension,loosenthespringplungeradjustmentsetscrews,thenslidetheplungerfurtherintothe,不可拆除的零部件blockandtightenthesetscrews.Toaccommodateadifferentsizesample,loosenthewireformadjustmentsetscrews,slidethewireformtotheappropriatelengthandtightensetscrews.Afteraninitialadjustment,mounttheextensometertothesampleto,十....售后服务checktightness.(Seefigare)所有引伸计不需要定期维护。图7当引伸计的行程过大,试样会发生破坏,这时我们可以进行手动限位,保证引伸计不被损坏。刀刃在长时间的使用后,会有所损坏,这客户不用担心,我们已经为每一个引伸计配备一套备用刀刃。发生损坏的引伸计可以跟本公司进行联系,我们的技术人员将会免费对其损坏情况进行评估,如果维修过程产生维修费用,我们会主动跟客户进行联系,提Springplungeradjustmentsetscrews,Wireformajustment,供合理的维修价格。当然最终是否接受并进行维修的主动权在客户。Figare3Setscrews引伸计必须连接到测量信号设备,以便采集测量数据,数据是直接读取的。Mountextensometer引伸计首次使用时,必须要先标定引伸计使用前,应先用引伸计标定仪来进行1.Usehandstomount.Assembleproceduce.Seefigare4标定,只有合格的才能使用。如果试验机控制系统的设置可以进行引伸计的测试,WANCEHoldSqueezeReleaseFigare4的标定程序。Iftheknifecdgesareeasilymadetoslipagainstthesample,additionalforcemaybe本引伸计和所有的试验机一样,都有一定的测试空间范围,这是一个行业标required.Alternatively.springorelasticbandsmaybeusedtoattachtheextensometer准所规定的。本引伸计允许不同的倾斜度测量。tothetestspecimen.Toinstalleitherspringsorelasticbands,thequickattackkitmustfirstberemoved.Thisisaccomplishedbyremovingthescrewsholdingthespring八标定plungerinplace.Scefigare51.引伸计的安装和调整在前面已作了说明,其变形范围必须是在标定设备的满量程范围内,连接的测量信号设备的灵敏度一定要满足引伸计的标定需求。2.引伸计安装时,标定仪一定要处在在零点位置,测量设备的读数要清零。3.引伸计标定要求从0到最大变形之间进行逐级标定,测量3组。可以根据Placeoffasteningscrew需要选择不同的测量点。一些采集数据控制系统根据引伸计的最大变形量来作出相应的设定。大多数材料的拉伸测试,精度最大一般是在变形最小的地方,所以Figare5在这个范围内变形量的选择相当重要。如果是进行材料断裂测试,标定的变形量Afterthequickattachkithasbeenremovedthespringsorelasticbandscanbe可以大一些,这个设定就不是很重要。总之,不同的长度,要求的精度会有所不attachedbyhookingthemtothemountingpost,stretchingthemaroundthesample同。我们的引伸计都是采用高精度的标定设备来进行标定的。考虑到所有应变式thenhookingthemtotheendofthepost.Seefigare6传感器都会存在少量的滞后性,所以引伸计回零时,应退过零点,待产生很小的负位移后在进行到零位,并相应将引伸计也重调到零,开始检验。这样可以减小材料的滞后性所带来的影响。4.检定周期引伸计的检定周期一般为12个月。客户可以选择自行标定,也可以选择送回本公司重新检定,我们会给出新的标定证书,附有新的“标定数据”Figare62.Mounttheextensometertothesample.Zeropinmustbeinplacewhenextensometerismountedtoensureaccurategaugelength九.常见问题处理3.RemovethezeropinfromtheextensometerItisrecommendedthataslight1.防潮处理如果引伸计沾上水,应马上进行干燥处理。使用吹风机吹干是一种turningactionbeappliedtothezeropinasitbeingremovedtominimizefriction很好的方法,但温度不可过高,以免引伸计出现变形。引伸计不可长时间暴露在4.Verifythattheoutputofthedeviceisnearzero.ifthereisazeroshiftinthedata,潮湿环境中,以免发生腐蚀或者整体变形,影响测量精度。如果引伸计由于潮湿thiscanbeeliminatedbyusingtheauto-tareonthesi